Hygienic solutions for wheelchair, decubitus mattresses bed bases and all other medical and revalidation devices.

Rehawash Systems

Validated cleaning and disinfection systems

Request a demo

Request a demo

Hygienic solutions for wheelchair, decubitus mattresses bed bases and all other medical and revalidation devices.

Rehawash Systems

Validated cleaning and disinfection systems

Request a demo

Request a demo

Our Models

The RehaWash wash cell with integrated cleaning and disinfecting system is a validated and certified hygienic process for maximum hygienic solutions.

It clearly exceeds the requirements of the Medical Products Act for the safe treatment of reusable aids – demonstrated by hygienic analyzes based on a complex series of tests.

Want to request information about our series?

Do you have any questions? Read some of our answers!

How long takes one cycle?

There are three cleaning programs and three cleaning and disinfecting programs. A complete cycle takes 8-12 minutes. In connection with the disinfection, a few minutes are required depending on the exposure time.

In addition, there are two special disinfection programs (validated disinfection and disinfection – hardness). These programs take up to 20 minutes and apply in conjunction with a listed disinfectants for hygiene expert opinions, including hygiene certificates.

How much cleaning agent do I need?

There are three cleaning programs and three cleaning and disinfecting programs. A complete cycle takes 8-12 minutes. In connection with the disinfection, a few minutes are required depending on the exposure time.

In addition, there are two special disinfection programs (validated disinfection and disinfection – hardness). These programs take up to 20 minutes and apply in conjunction with a listed disinfectants for hygiene expert opinions, including hygiene certificates.

How much water do you need pro cleaning cycle?

Per wash cycle about 35 liters of warm water are required (approximately 45 ° C).

Do you need warm water?

To clean effectively, warm water with a temperature of approx. 45 ° C is needed. Either the hot water is available at the customer or it is a washing cell with an integrated electric heating (hydraulically controlled instantaneous water heater max. 55 ° C) was used.

How long does it takes to get warm water?

The first wash cycle at the start of the day takes approx. 3 minutes longer since the water tank must be filled with warm water. If the water has not been pumped out the evening before and the wash cell is equipped with additional heating, the heating will continue until the set temperature has been reached.

What happens during the cleaning procedure?

The rehabilitation agent, which has entered the washroom of the RehaWash unit, is cleaned and disinfected with wash water from the water tank with the addition of cleaning solution and disinfecting solution according to the set program. After the washing time has elapsed, the wash water is pumped off and fresh water is filled into the tank. The rinsing operation then begins with the addition of rinsing solution. The rinse water remains in the water tank for the next wash cycle.

How long takes it to dry?

The first wash cycle at the start of the day takes approx. 3 minutes longer since the water tank must be filled with warm water. If the water has not been pumped out the evening before and the wash cell is equipped with additional heating, the heating will continue until the set temperature has been reached.

How many wheelchairs can be cleaned in one washing cycle?

Normally, only one reagent per wash cycle is treated. In a wash cell of size XL, B 904 or washing lines, several reheating agents can be cleaned and disinfected at the same consumption costs.

Is it possible to wash the covering?

In our cleaning and disinfecting systems everything can be cleaned and disinfected; Except textile- or velor-like covering, since they absorb too much water and require too long a drying time.

How to clean AD mattresses?

The cleaning and disinfecting of AD systems (semicritical medical device class IIa) is validated with all RehaWash wash cells. The AD systems are hung on a special rack and disinfected according to the hygienic certificate and certificate.

The drying of the AD mattresses takes place in the air or in special RehaWash drying systems.

Is any cleaning necessary before using a RehaWash system?

Highly contaminated rehabilitation agents should be pre-cleaned. Spraying the heavily soiled area with cleaning concentrate and a soaking will shorten the cleaning time.

Does the cleaning effect on metal components?

The effect of moisture is minimal since the spraying is carried out at short notice and with little pressure. A walk with a wheelchair in the rain puts the wheelchair far away.

Do we have to remove engines?

If the motors meet the IP standard for splash-protected articles, no problem is to be expected. Please contact the bed supplier for safety.

Are there any spots visible after cleaning?

The water droplets are softened by the use of a rinsing agent after the cleaning or disinfecting wash, leaving only a water film on the surfaces. This water film dries within a short time through the internal heat of the rehabilitation agent almost without any stain formation.

However, strongly calcareous water can still lead to limescale spots on the laundry, as well as to clogging nozzle rods and spray nozzles. The former reduces the cleaning result optically the latter impairs the cleaning or disinfecting results, so in this case the installation of an optional decalcification system is recommended.

Unique advantages of RehaWash Systems

Timesaving

A washing process with a RehaWash wash cell can be carried out within a few minutes.

Simple and mobile

The specially tested cleaning, disinfecting and rinsing programs are easy to operate from a control panel.

Certificated disinfection

All RehaWash wash cells are TÜV certified and therefore have all the necessary certifi-
cations and hygiene reports.

Safe for employees

Employees do not come into contact with the contamination of the cleaning agent during the washing process.

Environment-friendly

The use of biodegradable chemicals is tailored to the desired degree of cleaning or disinfection.

Fixed Costs

Each washing process is defined in terms of time, water consumption and consumption of treatment products.

News

Burmeier Facebook

Visit from our partner Burmeier to the RehaWash plant.

Medica 2017

MEDICA is the world’s largest event for the medical sector...

Burmeier Care Beds

Dali Wash The Dali range of care beds from Burmeier is the…

Partners & references

Burmeier GmbH

“A washing process with a RehaWash wash cell can be carried out within a few minutes.”

Bartrams Healthcare

“The specially tested cleaning, disinfecting and rinsing programs are easy to operate from a control panel.’”

Gialdi

“A washing process with a RehaWash wash cell can be carried out within a few minutes.”

Ergocare

Lautenschlaeger

Our Dealers

ZS-Medizintechnik

Quality Standards

All our systems have the following qualifications: